Diagnosis Procedure

1.CHECK AIR BAG MODULE AND SEAT BELT PRE-TENSIONER

Check the deployment of air bag module.

Is air bag module deployed? YES >> Replace the malfunctioning parts.

NO >> GO TO 2.

2.CHECK AIR BAG FUSE

Check 10 A fuse [No.3, located in fuse block (J/B)].

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace the fuse.

3.CHECK HARNESS CONNECTOR

Check the harness connector.

Is the inspection result normal? YES >> GO TO 4.

NO >> Replace harness connectors.

4.CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal? YES >> GO TO 5.

NO >> Replace wiring harness.

5.REPLACE AIR BAG DIAGNOSIS SENSOR UNIT

  1. Replace air bag diagnosis sensor unit. Refer to SR-28, "Removal and Installation".
  2. Check air bag warning lamp operation.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 6.

6.REPLACE COMBINATION METER

  1. Replace combination meter. Refer to MWI-77, "Removal and Installation".
  2. Check air bag warning lamp operation.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 1.

Symptom diagnosis
...

SRS Air bag warning lamp does not turn ON
Diagnosis Procedure 1.CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUIT Check combination meter unit power supply and ground circuit. Refer to MWI-52, "COMBINATION METER : Diagnosis Pr ...

Other materials:

CVT Oil warmer
Exploded View Transaxle assembly O-ring CVT oil warmer CVT fluid Removal and Installation REMOVAL WARNING: Do not remove the radiator cap when the engine is hot. Serious burns could occur from high pressure coolant escaping from the radiator. Wrap a thick cloth around the cap ...

Standardized relay
Description Normal open, normal closed and mixed type relays Relays can mainly be divided into three types: normal open, normal closed and mixed type relays. Type of standardized relays ...

Slip indicator lamp
Component Function Check 1.CHECK SLIP INDICATOR LAMP FUNCTION Check that slip indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON. Is the inspection result normal? YES >> Inspection End. NO >> Proceed to diagnosis proce ...

В© 2014-2025 Copyright www.nisentra.com