Nissan Sentra manuals

Nissan Sentra Service Manual: SRS Air bag warning lamp does not turn OFF

Nissan Sentra Service Manual / Restraints / SRS airbag control system / Symptom diagnosis / SRS Air bag warning lamp does not turn OFF

Diagnosis Procedure

1.CHECK AIR BAG MODULE AND SEAT BELT PRE-TENSIONER

Check the deployment of air bag module.

Is air bag module deployed? YES >> Replace the malfunctioning parts.

NO >> GO TO 2.

2.CHECK AIR BAG FUSE

Check 10 A fuse [No.3, located in fuse block (J/B)].

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace the fuse.

3.CHECK HARNESS CONNECTOR

Check the harness connector.

Is the inspection result normal? YES >> GO TO 4.

NO >> Replace harness connectors.

4.CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal? YES >> GO TO 5.

NO >> Replace wiring harness.

5.REPLACE AIR BAG DIAGNOSIS SENSOR UNIT

  1. Replace air bag diagnosis sensor unit. Refer to SR-28, "Removal and Installation".
  2. Check air bag warning lamp operation.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 6.

6.REPLACE COMBINATION METER

  1. Replace combination meter. Refer to MWI-77, "Removal and Installation".
  2. Check air bag warning lamp operation.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 1.

Symptom diagnosis
...

SRS Air bag warning lamp does not turn ON
Diagnosis Procedure 1.CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUIT Check combination meter unit power supply and ground circuit. Refer to MWI-52, "COMBINATION METER : Diagnosis Pr ...

Other materials:

P0117, P0118 ECT Sensor
DTC Logic DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition Possible cause P0117 ECT SEN/CIRC (Engine coolant temperature sensor 1 circuit low) An excessively low voltage from the engine coolant temperatu ...

Power supply and ground circuit
Av control unit Av control unit : diagnosis procedure Regarding wiring diagram information, refer to av-331, "wiring diagram". 1.Check fuse Check that the following fuses are not blown. Are the fuses blown? Yes >> replace the blown fuse after repairing the affected circuit. ...

Positive crankcase ventilation
Inspection 1.CHECK PCV VALVE With engine running at idle, remove PCV valve from rocker cover. A properly working valve makes a hissing noise as air passes through it. A strong vacuum should be felt immediately when a finger is placed over valve inlet. Is the inspection result normal? YES &g ...

В© 2014-2025 Copyright www.nisentra.com