REMOVAL OF LIQUID GASKET SEALING
Tool Number : KV10111100 (J-37228)

CAUTION:
Be careful not to damage the mating surfaces.
CAUTION:
Do not damage the mating surfaces.
LIQUID GASKET APPLICATION PROCEDURE


Use Genuine Silicone RTV Sealant, or equivalent. Refer to GI-21, "Recommended Chemical Products and Sealants".

Check to read the text of this manual.
(A) : Groov
Inside
CAUTION:
If there are specific instructions in the procedures contained in this manual concerning liquid gasket application, observe them.
Parts Requiring Angle Tightening
PreparationP0963 Pressure control solenoid A
DTC Logic
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
Possible causes
P0963
PC SOLENOID A
(Pressure Control Solenoid A
Control Circuit High)
The line pressure solenoid valve current is 200
mA or less c ...
Eps branch line circuit
Diagnosis procedure
1.Check connector
Turn the ignition switch off.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the eps control unit for damage,
bend and loose connection (unit
side and connector side).
Is the inspection result norm ...
Mixture ratio self-learning value
clear
Description
This describes how to erase the mixture ratio self-learning value. For the
actual procedure, follow the instructions
in “Diagnosis Procedure”.
Work Procedure
1.START
With CONSULT
Start engine and warm it up to normal operating temperature.
Select “SELF-LEARNI ...