Diagnosis procedure
1.Check connector
Is the inspection result normal? Yes >> go to 2.
No >> repair the terminal and connector.
2.Check harness for open circuit


Is the measurement value within the specification? YES >> GO TO 3.
NO >> Repair the BCM branch line.
3.Check power supply and ground circuit
Check the power supply and the ground circuit of the bcm. Refer to the following.
Is the inspection result normal? Yes (present error)>>replace the bcm. Refer to the following.
Yes (past error)>>error was detected in the bcm branch line.
No >> repair the power supply and the ground circuit.
Hvac branch line circuit
Can communication circuitCluster lid A
Removal and Installation
REMOVAL
Release cluster lid A clips and pawls using a suitable tool.
: Pawl
Metal clip
Remove cluster lid A.
INSTALLATION
Installation is in the reverse order of removal. ...
Basic inspection
Diagnosis and repair work flow
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
1.GET INFORMATION FOR SYMPTOM
Get detailed information from the customer about the symptom (the
condition and the environment when
the incident/malfunction occurs).
Check operation condition of the function th ...
VDC/TCS/ABS
Symptom Table
If ABS warning lamp and SLIP indicator lamp turn ON, perform
self-diagnosis.
NOTE:
1: The ABS does not operate when the speed is 10 km/h
(6 MPH) or less.
2: Under the following conditions, ABS is activated
and vibration is felt when brake pedal is lightly depr ...