Nissan Sentra manuals

Nissan Sentra Service Manual: BCM branch line circuit

Diagnosis procedure

1.Check connector

  1. Turn the ignition switch off.
  2. Disconnect the battery cable from the negative terminal.
  3. Check the terminals and connectors of the bcm for damage, bend and loose connection (unit side and connector side).

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair the terminal and connector.

2.Check harness for open circuit

  1. Disconnect the connector of BCM.
  2. Check the resistance between the BCM harness connector terminals.


Is the measurement value within the specification?


Is the measurement value within the specification? Yes >> go to 3.

No >> repair the bcm branch line.

3.Check power supply and ground circuit

Check the power supply and the ground circuit of the bcm. Refer to the following.

Is the inspection result normal? YES (Present error)>>Replace the BCM. Refer to the following.

YES (Past error)>>Error was detected in the BCM branch line.

NO >> Repair the power supply and the ground circuit.

Hvac branch line circuit
Diagnosis procedure 1.Check connector Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal Check the terminals and connectors of the a/c auto amp. For damage, ...

Can communication circuit
Diagnosis procedure 1.Connector inspection Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal. Disconnect all the unit connectors on can communication syste ...

Other materials:

Manual operation
Fan speed control Press the fan control buttons to manually control the fan speed. Press the AUTO button to return to automatic control of the fan speed. Air recirculation Press the air recirculation button to recirculate interior air inside the vehicle. The indicator light on the b ...

P0524 Engine oil pressure
DTC Logic DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition Possible cause P0524 ENGINE OIL PRESSURE (Engine oil pressure too low) An EOP sensor signal voltage applied to ECM remains lower than the specified ...

Diagnosis and repair workflow
Work Flow OVERALL SEQUENCE *1: Include 1st trip DTC. *2: Include 1st trip freeze frame data. DETAILED FLOW 1.GET INFORMATION FOR SYMPTOM Get the detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurred) using the ...

В© 2014-2026 Copyright www.nisentra.com