Nissan Sentra Service Manual: Anti-pinch inspection
Descriptio
n
If any of the following operations are performed, the initialization is
necessary for normal operation of antipinch
function.
- Disconnection and connection of battery cable from negative terminal.
- When power window main switch replaced.
- Electric power supply to power window main switch or power window motor
(driver side) is interrupted by
blown fuse or disconnection and connection of the negative terminal of
battery, etc.
- Disconnection and connection of power window main switch harness
connector.
- Removal of power window motor (driver side) from regulator assembly.
- Operation of regulator assembly as an independent unit.
- Removal and installation of glass.
- Removal and installation of door glass run.
Work Procedure
1.CHECK ANTI-PINCH FUNCTION
- Fully open the door window.
- Place a piece of wood near fully closed position.
- Close door glass completely with AUTO-UP.
- Check the following conditions.
- Check that glass lowers for approximately 150 mm (5.91 in.) without
pinching piece of wood and stops.
- Check that glass does not rise not when operating the power window main
switch while lowering.
CAUTION:
- Perform initial setting when AUTO-UP operation or anti-pinch
function does not operate normally.
- Check that AUTO-UP operates before inspection when system
initialization is performed.
- Do not check with hands and other body parts because they may be
pinched. Do not get
pinched.
>> END
Description
If any of the following operations are performed, the initialization is
necessary for normal operation of power
window system.
Disconnection and connection of battery cable from ne ...
Other materials:
Exhaust valve timing control
EXHAUST VALVE TIMING CONTROL : System
Description
SYSTEM DIAGRAM
INPUT/OUTPUT SIGNAL CHART
Sensor
Input signal to ECM
ECM function
Actuator
Crankshaft position sensor (POS)
Engine speed and piston position
Exhaust valve
timing control
Exhaust valve timing ...
Blower motor
Exploded View
Heating and cooling unit assembly
Blower motor
Front
Removal and Installation
Remove the glove box assembly. Refer to IP-22, "Removal and
Installation".
Disconnect the harness connector from the blower motor.
Remove the blower motor screws.
Remove ...
Basic inspection
Diagnosis and repair workflow
Work Flow
Overall sequence
Detailed flow
1.Get information for symptom
Get detailed information from the customer about the symptom (the condition
and the environment when the
incident/malfunction occurred).
>> GO TO 2.
2.Confirm the symptom
Try t ...
В© 2014-2026 Copyright www.nisentra.com