CAUTION:

When performing this inspection, always use a charged battery that has completed the battery inspection. (When the charging rate of the battery is low, the response speed of the voltage change will become slow. This can cause an incorrect inspection.)

  1. CHECK IPDM E/R

    1. CONSULT

      Select “Self Diagnostic Result” mode of “IPDM E/R”. Refer to CONSULT Function (IPDM E/R).

    Self-diagnostic results content

    No malfunction detected>>

    GO TO 2.

    Malfunction detected>>

    Check applicable parts, and repair or replace corresponding parts.

  2. CHECK OPERATION OF POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM

    1. CONSULT

      1. Start the engine.

      2. The selector lever is in “P” or “N” position and all of the electric loads and A/C, etc. are turned OFF.

      3. Select “ALTERNATOR DUTY” in “Active Test” mode of “ENGINE”, and then check the value of “BATTERY VOLT” monitor when DUTY value of “DUTY” is set to 40.0 %.

        “BATTERY VOLT”

        2 seconds after setting the DUTY value of “ALTERNATOR DUTY” to 40.0 %

        : 12 - 13.6 V

      4. Check the value of “BATTERY VOLT” monitor when DUTY value of “DUTY” is set to 80.0%.

        “BATTERY VOLT”

        20 seconds after setting the DUTY value of “ALTERNATOR DUTY” to 80.0 %

        : +0.5 V or more against the value of “BATTERY VOLT” monitor when DUTY value is 40.0 %

    Is the inspection result normal?

    YES >>

    Inspection End.

    NO >>

    GO TO 3.

  3. CHECK ECM

    1. CONSULT

      Select “Self Diagnostic Result” mode of “ENGINE”. Refer to CONSULT Function.

    Is the inspection result normal?

    No malfunction detected>>

    GO TO 4.

    Malfunction detected>>

    Check applicable parts, and repair or replace corresponding parts.

  4. CHECK HARNESS BETWEEN GENERATOR AND ECM

      1. Ignition switch OFF.

      2. Disconnect generator connector and ECM connector.

      3. Check continuity between generator harness connector and ECM harness connector.

        Generator

        ECM

        Continuity

        Connector

        Terminal

        Connector

        Terminal

        F15

        2

        F25

        98

        Yes

      4. Check continuity between generator harness connector and ground.

        Generator

        Continuity

        Connector

        Terminal

        F15

        2

        Ground

        No

    Is the inspection result normal?

    YES>>

    Replace ECM. Refer to Removal and Installation.

    NO>>

    Repair harness or connectors between ECM and generator.

Power Generation Voltage Variable Control System Operation Inspection
...

B Terminal Circuit
...

Other materials:

Primary speed sensor
Exploded View Transaxle assembly O-ring Primary speed sensor : Always replace after every disassembly. : N m (kg-m, in-lb) : Genuine NISSAN CVT Fluid NS-3 Removal and Installation REMOVAL Disconnect the primary speed sensor connector. Remove the primary speed sensor. ...

Regulatory Information
FCC Regulatory information CAUTION: To maintain compliance with FCC’s RF exposure guidelines, use only the supplied antenna. Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC regulations. Operation is subject to the following two cond ...

Ecm, Bcm, Ipdm E/r
List of Ecu Reference List of ECU Reference ECU Reference ECM Values On The Diagnosis Tool ...

© 2014-2026 Copyright www.nisentra.com