Component Function Check
1.CHECK VDC OFF SWITCH OPERATION
Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated.
Is the inspection result normal? YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC-92, "Diagnosis Procedure".
Diagnosis Procedure
Regarding Wiring Diagram information, refer to BRC-44, "Wiring Diagram".
1.CONNECTOR INSPECTION
Turn ignition switch OFF.
Disconnect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Check connectors and terminals for deformation, disconnection, looseness or damage.
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace as necessary.
2.CHECK VDC OFF SWITCH
Check VDC OFF switch. Refer to BRC-93, "Component Inspection".
Is the inspection result normal? YES >> GO TO 3.
NO >> Replace VDC OFF switch. Refer to BRC-112, "Removal and Installation".
3.Check VDC OFF Switch signal
With CONSULT.
Connect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Turn ignition switch ON.
In “DATA MONITOR” select “OFF SW” and check VDC OFF switch signal.
Is the inspection result normal? YES >> Refer to BRC-51, "Work Flow".
NO >> GO TO 4.
4.Check VDC OFF Switch circuit
Turn ignition switch OFF.
Disconnect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
Check continuity between ABS actuator and electric unit (control unit) connector E33 terminal 15 and VDC OFF switch connector M64 terminal 6.
Check continuity between ABS actuator and electric unit (control unit) connector terminal E33 terminal 15 and ground.
Is the inspection result normal? YES >> GO TO 5.
NO >> Repair or replace malfunctioning components.
5.Check vdc off switch ground circuit
Check continuity between VDC OFF switch connector M64 terminal 8 and ground.
Is the inspection result normal? YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-110, "Removal and Installation".
NO >> Repair or replace malfunctioning components.
Component Inspection
1.Check vdc off switch
Turn ignition switch OFF.
Disconnect VDC OFF switch connector.
Check continuity between terminals of VDC OFF switch connector.
Is the inspection result normal? YES >> Inspection End.
NO >> Replace VDC OFF switch. Refer to BRC-112, "Removal and Installation".
Work Flow
STEP
DESCRIPTION
STEP 1
Get detailed information about the conditions and the
environment when the incident occurred.
The following are key pieces of information required to make a good
analysis:
WHAT
Vehicle Model, Engine, Transmission/Transaxle and ...
Dtc/circuit diagnosis
Eco mode switch
Component function check
1. Check eco mode switch operation
Turn ignition switch on.
Check ECO mode indicator lamp turns ON/OFF on combination meter when
turn ECO mode switch ON/
OFF.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Proceed to DM ...
Spark plug
Exploded View
Ignition coil
Spark plug
Rocker cover
Removal and Installation
REMOVAL
Remove engine cover. Refer to EM-24, "Exploded View".
Remove ignition coil. Refer to EM-46, "Exploded View".
Remove spark plug using suitable tool.