Nissan Sentra Service Manual: Precaution for work
- When removing or disassembling each component, be careful not to damage
or deform it. If a component
may be subject to interference, be sure to protect it with a shop cloth.
- When removing (disengaging) components with a screwdriver or similar
tool, be sure to wrap the component
with a shop cloth or vinyl tape to protect it.
- Protect the removed parts with a shop cloth and prevent them from being
dropped.
- Replace a deformed or damaged clip.
- If a part is specified as a non-reusable part, always replace it with a
new one.
- Be sure to tighten bolts and nuts securely to the specified torque.
- After installation is complete, be sure to check that each part works
properly.
- Follow the steps below to clean components:
- Dip a soft cloth into lukewarm water, wring the water out of the cloth
and wipe the dirty area.
- Then rub with a soft, dry cloth.
- Dip a soft cloth into lukewarm water with mild detergent (concentration:
within 2 to 3%) and wipe the dirty
area.
- Then dip a cloth into fresh water, wring the water out of the cloth and
wipe the detergent off.
- Then rub with a soft, dry cloth.
- Do not use organic solvent such as thinner, benzene, alcohol or
gasoline.
- For genuine leather seats, use a genuine leather seat cleaner.
Precaution for procedure without cowl top cove.R.
When performing the procedure after removing cowl top cover, cover
the lower end of windshield with urethane, etc to prevent damage to
windshield.

The Supplemental Restraint System such as “AIR BAG” and “SEAT BELT PRE-TENSIONER”,
used along
with a front seat belt, helps to reduce the risk or severity of injury to the
dri ...
WORKING WITH HFC-134a (R-134a)
CAUTION:
CFC-12 (R-12) refrigerant and HFC-134a (R-134a) refrigerant are
not compatible. Compressor malfunction
is likely to occur if the refrigerants are mixe ...
Other materials:
Preparation
Special Service Tools
The actual shape of the tools may differ from those illustrated here.
Commercial Service Tools
...
Sensor power supply 2 circuit
Description
ECM supplies a voltage of 5.0 V to some of the sensors systematically divided
into 2 groups, respectively.
Accordingly, when a short circuit develops in a sensor power source, a
malfunction may occur simultaneously
in the sensors belonging to the same group as the shorted-circui ...
How to Follow Test Groups in Trouble Diagnosis
Test group number and test group title
Test group number and test group title are shown in the upper portion of
each test group.
Work and diagnosis procedure
Start to diagnose a problem using procedures indicated in enclosed test
groups.
Questions and results
...